100DX Syringe Pump datasheet - PRODUCT DATA Teledyne Isco Syringe Pumps 100DX High Pressure Syringe Pump 10,000 PSI FOR HIGH PRESSURE APPLICATIONS The 100DX syringe pump provides precise, predictable flow and pressure control at flow rates from sub-microliter to 50 ml/min. Exceptional low-flow stability at up to 10,000 psi makes this the ideal pump for high pressure applications from deep well core analysis to multi-dimensional capillary LC using small-bore packed capillary columns. The D-series controller has a keypad and LCD, as well as built-in and optional interfaces for computer control and other devices. Programming is easy and flexible, with instant access to menu screens even when the pump is running.

SALMSON Pumps - All the products on Direct. Industrydiaphragm pump. Flow rate: 1. Diaphragm Pumps. Nordson offers a complete line of liquid. The Isco D Series Syringe Pumps Instruction Manual. M-1784, - Manual - For sale surplus used equipment from HiTechTrader Price Mt Holly NJ. Series Flow Meters - Teledyne Isco - PDF Catalogue. 0 Series is backed by 3. You can depend on Isco technology to meet your needs in an increasingly. Computer Ghost Hunting Software Torrent.

Isco Pump Manual

This allows you to change operating parameters on the fly. An optional extension cable lets you locate the controller up to 50 feet from the pump. The 100DX pump module has a single-ratio drive train with autolubricating gears for long life and low maintenance. Special fittings are used to prevent leaks and ensure safety at maximum pressure.

Wetted materials are compatible with most aqueous and organic liquids, corrosive solutions, heated fluids, liquefied gases, viscous fluids, or slurries and pastes. Applications Precision fluid addition in research and manufacturing Reactant feed in chemical process development, catalyst evaluation, plastic formulation Accurate metering of liquefied gases Standard Controller Features Operating Modes Constant flow or pressure with up to three pumps Gradient LC programming Flow or pressure programming with a dual pump External Interface RS232 serial interface Analog voltage inputs Digital inputs and outputs Teledyne Isco, 4700 Superior Street, Lincoln, NE 68504 USA Phone: (800) 228-4373 / (402) 464-0231 iscoinfo@teledyne.com / www.isco.com.

4200 Series Open Channel Flow Meters When you need a monitoring system that’s accurate, versatile, and easy to use, turn to open channel flow meters from Isco. Our 4200 Series is backed by 30 years of experience in flow measurement. You can depend on Isco technology to meet your needs in an increasingly complex monitoring environment. Maximum Accuracy Nothing else matters if your flow meter can’t measure flow accurately. But inaccuracies result when a single measurement technology is used in a variety of applications. The 4200 Series offers you a choice of four measurement technologies, so you. User-friendly Programming and Data Collection Fast and Easy Programming The 4200s are so easy to program, you’ll rarely need the instruction manual.

Just use the tactile keypad to respond to simple questions on the two-line, 80-character LCD. For added convenience, the LCD is backlit, so it’s easy to read – even in the darkest manholes. The 4200 Series contains built-in flow conversions for most applications, or you can enter data points or an equation for special situations. When programming is complete, data is displayed in selectable units of measure. Exclusive Built-in Printer Our 4200 Series. Choose the Best Technology For Your Applications No single technology is suitable for all open channel flow measurement applications. Isco offers you a choice of ultrasonic, submerged probe, bubbler, and area velocity flow meters.

The 4200 Series includes the 4210 Ultrasonic, 4220 Submerged Probe, 4230 Bubbler, and 4250 Area Velocity Flow Meters. Now you can choose the most accurate technology for each of your monitoring sites. Please refer to the Flow Measurement Technology Selection Guide on the back cover for more information. 4210 Ultrasonic—for flow measurement in streams containing harsh. 4220 Submerged Probe—ideal for sites where wind, steam, foam, or turbulence exist. The probe is mounted at the bottom of the channel and measures the pressure of the liquid above the probe to determine the depth of the flow stream.

The 4220 converts the level reading into flow rate. 4230 Bubbler—resists damage by lightning, debris, and corrosive flow stream chemicals. The 4230 uses an internal air compressor to force air from a bubble tube submerged in the flow stream. The depth of the flow is determined by measuring the pressure needed to force bubbles out of the line. The 4230 then converts.

More Than a Flow Meter Water Quality Monitoring In addition to measuring flow rate, Isco 4200 Series Flow Meters can continuously monitor important water quality parameters. Simply connect an Isco 201 pH/Temperature Module to your 4200 Series Flow Meter. Parameter Module Specifications 201 Parameter Module Size (L x W x D) Weight Material Enclosure Power Cable Length (module to flow meter) Temperature Probe 8.5 in x 4.75 in x 3.5 in 21.6 cm x 12.1 cm x 8.9 cm 2.5 lbs 1.1 kg Structural foam molded polystyrene NEMA 4X IP65 10 to 14V DC, 10 mA Maximum (supplied by 4200 Series Flow Meter) 15 ft (4.6.